removed older duplicate draft text

jlpoole 2026-02-20 18:08:51 -08:00
commit 984c2e0c56

@ -4,15 +4,6 @@
Each unit sends Lora message every 10 seconds and receives other 3 three units messages. Send and Receives are logged on the SD card. GPS is taken (I think) before each transmission. OLED displays incoming messages from other units.
Readings taken at 2:35 PM after I turned off units at 11:02 AM
From Log
Start End Fluke Measured 3 hrs later
Ed 4.172 3.708 3.763
Dan 4.158 3.738 3.752
Cy 4.145 3.665 3.665
Bob 4.172 3.708 3.716
Amy - not used
**Start** and **End** times are from logs reading values from the T-Beams's AXP2101 power-management IC (PMU). Fluke 87 V readings are from in-place battery ends with units powered down and not connected to USB taken at 2:35 PM after I powered down the units at 11:02 AM.
| Unit | Start | End | Fluke|